Sıcak Ürün:% s
AMC 200(L) AC multi-circuit intelligent power acquisition and monitoring device is mainly used for the full electric parameter measurement of multiple circuits, and can simultaneously access the current input of 8 three-phase circuits or 24 single-phase circuits at most.It can measure voltage, current, power, power factor and other parameters.
Main Feature
●Funtion:full power parameter measurement, Active 2DI+Passive 4DI+2DO, 4 NTC Temperature, 1T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485(Modbus RTU protocol), 4G
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Parameter
| Technical Parameter | Technical Indicator | ||
| Input | Frequency | 45~65Hz | |
| Voltage | Rating: AC 3×220V/380V | ||
| Overload: 1.2 times rated (continuous); 2 times rating value/1 second | |||
| Power consumption: ≤0.5VA (per channel) | |||
| Current | Rating: AC xxxA/50mA, need external transformer | ||
| Overload: 1.2 times rated (continuous); 10 times rating value /1 second | |||
| Power consumption: ≤0.5VA (per channel) | |||
| Function | Pulse Output | Output mode: open collector optocoupler pulse (default 400imp/kWh) | |
| Communication | Modbus-RTU or YD/T 1363 protocol(use in China);Baud rate 1200~38400 | ||
| Switch | Input | ||
| Output | Output mode: relay normally open contact output;
Contact capacity: AC 250V/3A or DC 30V/3A; |
||
| NTC Temperature Measurement | Temperature: -20~100℃ (accuracy ±2℃) | ||
| Temp&Humidity
Measurement |
Temperature: -20~100℃ (accuracy ±2℃); Humidity: 20-90%RH (accuracy ±5%RH) | ||
| Measurement accuracy | Frequency 0.05Hz, voltage and current 0.5 level, active power 1 level; | ||
| Auxiliary power supply | AC/DC 85 ~ 265V; Power consumption ≤10VA | ||
| Security | Power Frequency Withstand Voltage | >AC 2kV/1min | |
| Insulation Resistance | Input and output end to the housing>100MΩ | ||
| Environment | Operating temperature: -20℃ ~ +60℃;
Storage temperature: -40℃ ~ +70℃; Relative humidity: ≤95% no condensation; Altitude: ≤2500m; |
||
| Electromagnetic compatibility | Surge (impact) immunity test level 4 | ||
| Electrostatic discharge immunity test level 3 | |||
| Electrical fast transient pulse group immunity test level 3 | |||

Network

Installation


Sıcak Ürün:% s

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.