ADL200W and ADL400W Series DIN-Rail Mounted Multifunctional and Dual Circuits Electric Energy Meter With External Current Transformer is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc.The product has the advantages of high precision, small volume, high respondent speed and convenient installation. It can monitor and measure real-time power and other power parameters, support protocols such as Modbus-TCP and http, and communicate with inverters or energy management systems (EMS) via Wi-Fi or Lora communication to achieve functions such as anti-reverse flow, regulating power generation, and battery charging and discharging. It can be bidirectionally measured to achieve energy management for household distributed photovoltaic systems.
Main Feature
● Single phase
● Rated voltage: AC 230V;
● Voltage input range: 0.8Unom ~ 1.2Unom
● Minimum current: 0.3A
● Accuracy: 0.5
● Transitional current:1.5A
● Basic current: 30A
● Communication: RS485(Modbus-RTU), WiFi
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Standard&Certificate: CE-RED, ROHS, REACH, SGS;
Dimension
Parameter
|
Item |
Performance Parameters |
|||
|
Model Series |
ADL200W |
ADL400W |
||
|
Measurement |
Grid |
Single-phase |
Three-phase four-wire |
|
|
Voltage |
(Unom) Nominal voltage |
230V |
3×230/400V |
|
|
Input Range |
0.8Unom ~ 1.2Unom |
|||
|
Overload |
1.2 times rating (continuous) 2 times the rating for 1 second |
|||
|
Power consumption |
<2w, <10VA |
|||
|
Accuracy class |
Error ±0.5% |
|||
|
Current |
Minimum current |
0.3A |
||
|
Transitional current |
1.5A |
|||
|
Basic current |
30A |
|||
|
Maxinum current |
D16:Imax = 120A |
|||
|
overcurrent |
30 times the maximum current for 20ms |
|||
|
Power consumption |
<1W, <1VA |
|||
|
Accuracy class |
Error ±0.5% |
|||
|
Power |
Active, reactive, apparent power, error ±1.0℅ |
|||
| Frequency |
50Hz ,Error±0.5% |
|||
Wiring
Network

Application
Sıcak Ürün:% s

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.